Installation of the Single Room Pack for Underfloor Heating
The Compact UFH System is designed for wall fixing and ideally should be
mounted in a horizontal position with the electrical connection box uppermost.
However, it can also be mounted vertical to pump up or down if desired.
Provision should be made to vent air to protect pump from cavitation.
The unit must not be floor mounted or in any position that inclines the pump shaft
vertical. Refer to the pump installation leaflet enclosed.
Choose the location for the unit ensuring adequate clearance and
accessibility
for pipework and any subsequent maintenance. This is particularly important
if
enclosed within a cupboard space for example.
Locate the unit on the wall and mark the hole fixing positions through the
bracket.
Take care to protect any electrical equipment and cables during handling.
When connecting the pipe to the manifold use the cutter supplied to cut the pipe square then
calibrate the cut end to round the pipe ready to accept the compression adaptor. As the adaptor has
integral ‘O’ rings it is not essential to use further sealant such as PTFE tape.