Installation of the Reliance Control Pack for our Underfloor Heating Manifolds
2.4
Slip the 11/2″ pump nut over the flange on the flow connection elbow and then connect the elbow to the flow manifold by means of the 1″ MBSP
connection onto the flat faced union connection (ZCON 970 200)
previously installed, remembering to fit the 1″ fibre washer (ZWAS 219 042)
beforehand.
2.5
Slide the pump (PUMP 950 003) into position
between the 2 flat faced connections
ensuring that the direction of flow is correct
and that the 2 rubber washers are in position.
Tighten the pump union connections
work with manifolds of all types on 210mm centres. The Manifold Control Pack is a bolt on unit providing a quick and simple
system to install.
SECTION 2 – INSTALLATION
Before beginning the installation firmly fix the distribution manifolds to the wall leaving enough room beside the manifold to fit the control pack. (see dimensions)
2.1.
Before beginning the installation of the Manifold Control Pack, identify all of the components in the pack.
2.2
Assemble the 1″MBSP x flat faced adapters
(ZCON 970 200) to both the flow and return
manifold ball valves taking care to insert the
1″ fibre washer (ZWAS 219 042) beforehand.
Tighten the adapters into the ball valves by
removing the slip nut (ZNUT 970 200) and using
the flats on the adapter itself to tighten into the
ball valve and then re-fit the slip nut, alternatively the adaptor can be
fitted using a 16mm allen key.
2.3
Connect the Thermomix UFH control valve
(HEAT 970 200) to the return manifold by means
of the 1″ MBSP connection onto the flat faced
union connection (ZCON 970 200) previously
installed, remembering to fit the 1″ fibre washer
(ZWAS 219 042) beforehand.