Archive for July, 2008
Underfloor Heating in Edgbaston, Birmingham
Victorian house, two floors – underfloor heating throughout the property.
Typical Project Information for Underfloor Heating
Unit 1 – FF – Manifold located centrally
Pipe spacing c/c 200 mm. Max loop length 110 m. Try to use all the pipework supplied, but you will always have waste. Just make sure you have enough pipe to come back to the manifold, the pipe is marked every metre.
Loop lengths are only approximates!
Layout suggested is;
Unit 1 – FF; (Made it a 12 c manifold just in case)
Five room thermostats (2 core + earth). 11 CIRCUIT MANIFOLD. Approx. 160 sqm.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
KITCHEN/DINING – 400 M – ONE ROOM THERMOSTAT
ENTRANCE – 100 M – ONE ROOM THERMOSTAT
BEDROOM/BATHROOM – 100 M AND 50 M – ONE ROOM THERMOSTAT
BEDROOM/WARDROBE – 100 M AND 50 M – ONE ROOM THERMOSTAT
MASTER BEDROOM/BATHROOM – 100 M AND 100 M – ONE ROOM THERMOSTAT
Unit 2 – FF; (Made it at 12 c manifold just in case)
Five room thermostats (2 core + earth). 10 CIRCUIT MANIFOLD. Approx. 165 sqm.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
KITCHEN/LIVING – 400 M – ONE ROOM THERMOSTAT
ENTRANCE – 90 M – ONE ROOM THERMOSTAT
BEDROOM/BATHROOM – 100 M – ONE ROOM THERMOSTAT
BEDROOM/BATHROOM – 110 M – ONE ROOM THERMOSTAT
MASTER BEDROOM/BATHROOM – 300 M – ONE ROOM THERMOSTAT
Unit 3 – SF;(Made it an 8 c manifold just in case)
Two room thermostats (2 core + earth). 6 CIRCUIT MANIFOLD. Approx. 100 sqm.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
KITCHEN/LIVING – 500 M – ONE ROOM THERMOSTAT
ENTRANCE – 100 M – ONE ROOM THERMOSTAT
Unit 4 – SF;(Made it an 10 c just in case)
One room thermostats (2 core + earth). 8 CIRCUIT MANIFOLD. Approx. 135 sqm.
LOOP LAYOUT (ONLY APPROXIMATE LOOP LENGTHS)
KITCHEN/LIVING/ENTANCE – 800 M – ONE ROOM THERMOSTAT