Category: News

  1. Underfloor Heating Manifolds Positions

    Careful consideration should be given to the location of the underfloor heating manifolds at the inital stage of the project.  Underfloor Heating manifolds should be located as centrally as possible in the building so that the lenghts of the pipe routing between manifolds and the indiviudal heating zones is kept to a minimum.  This will help to […]

    Read more /

  2. Warm Water Underfloor Heating

    Passive self-regulation for underfloor heating Although underfloor heating systems are used in association with temperatures controls with different degrees of sophistication, the underfloor heating system provides its own passive self regulation. Floor temperatures are slightly higher then those of the room air. A rise in air temperature due to solar gain or increased occupancy means that […]

    Read more /

  3. Underfloor Heating, Chippenham, Wiltshire

    55 sqm concrete floor underfloor heating for Chippenham.  Four underfloor heating zones.  As below; – Family room – 110 m – one room thermostat – Study – 50 m – one room thermostat – Utility – 50 m – one room thermostat – Hall/WC – 90 m – one room thermostat Below is the underfloor […]

    Read more /

  4. Underfloor Heating, Barnsley, Yorkshire

    75 sqm underfloor heating system with six programmable digital room thermostats. Our local underfloor heating installer for the north of england will install the underfloor heating system. GF is 40 sqm screeded floor with 65 mm screed and 75 mm HD insulation.  The system will use a two port manifold.  One loop is for the […]

    Read more /

  5. Underfloor Heating Mixing Valve Set Up

    The thermostatic blending valve of our underfloor heating systems has a number of preset temperature settings. These range between 35°C and 60°C, as shown below: Min 35°C 1 40°C 2 44°C 3 48°C 4 50°C 5 54°C 6 58°C Max 60°C Initial settings of the thermostatic blending valve (after the heat up/screed drying period) should […]

    Read more /

  6. Danfoss Wiring Centre FH-WC Technical Information

    The FH-WC offers an eight zone wiring centre for underfloor heating systems that use hard-wired thermostats. With each of its eight outputs, the device can connect thermal actuators to the thermostats located in each room the underfloor heating is installed in. As the FH-WC is designed for use with water-based underfloor heating systems, it works […]

    Read more /

  7. Instructions for the TP5000 Si Danfoss Room Thermostat for Underfloor Heating

    TP5000 Si Features: Stylish modern design Large easy to read LCD display Easy to programme and operate Battery powered for ease of installation Service interval function Factory set clock Automatic BST/GMT time change Hard wired model Many additional features The TP5000 Si is an easy to install-and-use 5/2 day programmable room thermostat which offers up […]

    Read more /

  8. Underfloor Heating Fault Finding

    FAULT FINDING SHEET In the event that your underfloor heating (UFH) system is not working correctly, here are some points to check to help find the cause of the problem: Check that the air is completely out from the system. Do not fill from the boiler; fill the UFH system as described in the instructions. […]

    Read more /